Product Instructions:
Please pay attention for your first use. You need wait 6s after your setting data, the module will save the date you have set after 6s
Short press button SET:If you start the time setting mode , Nixie tube will blink. You could adjust the time T1 and T2 by button+ and button-. Please wait 5s after your setting date, the module will save the date you have set after 5s
Long press button SET:if you start the parameter setting mode. There are two group parameter for your choice :P0 and P1. You could switch P0 or P1 by short press SET. Under the parameter P0 and P1,you could set the timing mode by the button+ and button-
P0–0:Timing time mode :0—999s
P0–1:Timing time mode :0—999min
P0–2:Timing time mode :0—999h
P1–0:The relay will connect after you delay the T1 time
P1–1:The relay will disconnect after you delay the T1 time
P1–2:The relay will connect after you delay the T1 time first, Then the relay will disconnect after you delay the T2 time , it finish
P1–3:The relay will disconnect after you delay the T1 time first, Then the relay will connect after you delay the T2 time , it finish
P1–4:The relay will connect after you delay the T1 time first, Then the relay will disconnect after you delay the T2 time , it is cyclic
P1–5:The relay will disconnect after you delay the T1 time first, Then the relay will connect after you delay the T2 time , it cyclic
Example:A customer needs 10 seconds to start up and 20 seconds off. Setup is as follows:
T1 set time 10, T2 set time 20
P0 — 0 (T1 time range is seconds)
P1–5 (timer work mode)